521B Sentrol® Conventional |
|
|
Two wire photoelectric smoke detector with CleanMe™. Monitors sensitivity and operational status and provides visual and remote trouble status if out of sensitivity range or fails internal diagnostics. (6-24VDC) |
|
|
521BXT Sentrol® Conventional |
|
|
Two wire photoelectric smoke detector with CleanMe™ and 135º fixed rate of rise heat detector. (6-24VDC) |
|
|
525 Replacement Optical Chamber |
|
|
Replacement optical chamber snaps in for easy servicing of 521LX/LXT, 521B/BXT smoke detectors. |
|
|
|
|
Allows functional testing of 521LX/LXT smoke detectors. |
|
|
|
|
The 32-character LCD readout with full text display of system events and menu prompts make the 630F an efficient and easy-to-use keypad. The 630F operation is protected by either the keyswitch or a user code. The keyswitch enables single-button user operation of the Alarm Silence, System Reset, System Test, and Fire Drill features. Backbox and trim frame included. (8.5 - 15 VDC) |
|
|
|
|
The 690F Fire Command Keypad is a 32-character alphanumeric LCD keypad that provides a backlit keyboard, self-test diagnostics, 2-button Panic keys, and Power LED. The plain English, full text menu makes this keypad user-friendly and easy to use. The keypad backlighting turns red in alarm condition and sounds an alert tone. (8 - 16 VDC) |
|
|
|
|
The 802 offers a choice of eight international alerting sounds: Horn, Bell, March-Time Horn, Code-3 Tone, Code-3 Horn, Slow Woop, Siren, and Hi/Low Tone. Code-3 Tone & Horn patterns comply with NFPA/ANSI Temporal Pattern specification. Filtered or FWR. UL listed for indoor, ceiling and wall mount. (12 or 24 VDC) |
|
|
|
|
A high quality, die-cast metal, dual action manual pull station with SPST contacts and terminal strip connections. Contacts are gold plated to avoid corrosion. The 850 is in compliance with the latest requirements of the ADA. |
|
|
850-SB Surface Mount Backbox |
|
|
A 1 1/2" deep indoor back box for installations requiring surface mountings on masonry or other non-penetrable surfaces. |
|
|
|
Selectable Horn or Code-3 Tone |
|
The 803 provides a selectable continuous Horn or Code-3 tone when constant voltage from a Fire Alarm Control Panel is applied. Each tone has two settings: Continuous Horn Tone or Temporal Code 3. (12 or 24 VDC).
Wheelock model number: NH-12/24
|
|
|
|
|
Sound diffuser seven types of electronic sirens.
|
|
|
|
|
The 904 Horn offers more features with less current and zero inrush. Provides a selectable choice of either continuous horn or temporal pattern (code 3) when constant voltage from the FACP is applied. (24 VDC)
|
|
|
|
|
The XR5FC Commercial Fire Alarm Control panel, in a 340FC enclosure with a lock features built-in 2-line dialers, 500mA of auxiliary power, one Class A (Style D) zone for sprinkler supervision, a 1.5 Amp alarm bell output, and four Class B (Style A) smoke detector zones.
|
|
|
|
|
The XR5FC Fire Alarm Control panel provides built-in 2-line dialers, 500mA of auxiliary power, one Class A (Style D) zone for sprinkler supervision, a 1.5 Amp alarm bell output, and four Class B (Style A) smoke detector zones. The Waterflow package combines the capability of the panel with the following products.
· XR5FC Fire Alarm Control Panel
· 340FC Enclosure
· 690F-R LCD Keypad
· 866 Notification Module
· 320 Wire-in Transformer
· 356-7 Phone Cords (2)
|
|
|
|
|
2 Spot Light, Metallic Box
|
|
|
SLR-835BH Smoke/Heat Detector |
|
Photoelectric Smoke/Heat Detector |
|
The SLR-835B, a combination smoke and heat detector, utilizes two built-in bi-colored LEDs for indication of status. The smoke chamber consists of a pulsing LED light source and a silicon photo diode receiving element. A low profile and clean lines are suited for architecturally sensitive environments. Detector and base in one unit. (8-35VDC)
|
|